Y_EC_AddressToId

Image
Mapping from slave station address to the slave Id
Background: Required to get the index in the EtherCAT diagnostic component variable.

Parameters

* Parameter Data Type Description Default
VAR_INPUT
B Execute BOOL Upon the rising edge of the Execute input, all other inputs are read and the function block becomes operational. If an input needs to be modified, the value will have to be changed and the Execute input will have to be re-triggered. FALSE
E StationAddress WORD Station Address of addressed EtherCAT slave WORD#0
VAR_OUTPUT
B Done BOOL The Done output is set to TRUE when the commanded action has completed successfully. If another function block takes control before the action is completed, the Done output will never become TRUE. This output is reset when Execute becomes FALSE.
B Busy BOOL For function blocks with Execute input, the Busy output is set to TRUE upon the rising edge of the Execute, and set to FALSE when Done, CommandAborted or Error outputs becomes TRUE. In the case of a function block with an Enable input, Busy indicates that the function block is operating, but may not be ready to provide valid outputs.
B Error BOOL The Error output is set to TRUE if an error has occurred during the operation of the function block. The output is cleared when the Execute or Enable input becomes FALSE.
E ErrorID UINT The ErrorID output provides the identifier of the error when there is an active error in the function block execution. The output is cleared when the Execute or Enable input becomes FALSE.
E SlaveId UDINT SlaveId which belongs to INPUT StationAddress

Notes

Error Description

See the Function Block ErrorID List.

 


This help information is valid for iCube Engineer Online Help 2025.6