MC_ReadBoolParameter
The
MC_ReadBoolParameter
function block reads the value of an axis specific Boolean parameter and is for controller side parameters only. For drive side parameters, refer to
Y_ReadDriveParameter.
Parameters
| * | Parameter | Data Type | Description | Default |
|---|---|---|---|---|
| VAR_IN_OUT | ||||
| B | Axis | AXIS_REF | Logical axis reference. | |
| VAR_INPUT | ||||
| B | Enable | BOOL | The function block will continue to execute every scan while Enable is TRUE and there are no errors. | FALSE |
| B | ParameterNumber | UINT | Controller parameter number. Refer to parameters with BOOL Data Type in the Axis Parameter List. | UINT#0 |
| VAR_OUTPUT | ||||
| B | Valid | BOOL | The Valid output indicates that the function block is operating normally and the outputs of the function block are valid. | |
| B | Busy | BOOL | For function blocks with Execute input, the Busy output is set to TRUE upon the rising edge of the Execute, and set to FALSE when Done, CommandAborted or Error outputs becomes TRUE. In the case of a function block with an Enable input, Busy indicates that the function block is operating, but may not be ready to provide valid outputs. | |
| B | Error | BOOL | The Error output is set to TRUE if an error has occurred during the operation of the function block. The output is cleared when the Execute or Enable input becomes FALSE. | |
| E | ErrorID | UINT | The ErrorID output provides the identifier of the error when there is an active error in the function block execution. The output is cleared when the Execute or Enable input becomes FALSE. | |
| B | Value | BOOL | Value of the parameter. | |
Notes
Refer to boolean parameters in the Axis Parameter List.
Error Description
See the
Function Block ErrorID List
Example
Instance of
MC_ReadBoolParameter
reading boolean parameter 1222 (LimitAccelEnable) which is TRUE by default.