MC_ReadBoolParameter

Image
The MC_ReadBoolParameter function block reads the value of an axis specific Boolean parameter and is for controller side parameters only. For drive side parameters, refer to Y_ReadDriveParameter.

Parameters

* Parameter Data Type Description Default
VAR_IN_OUT
B Axis AXIS_REF Logical axis reference.
VAR_INPUT
B Enable BOOL The function block will continue to execute every scan while Enable is TRUE and there are no errors. FALSE
B ParameterNumber UINT Controller parameter number. Refer to parameters with BOOL Data Type in the Axis Parameter List. UINT#0
VAR_OUTPUT
B Valid BOOL The Valid output indicates that the function block is operating normally and the outputs of the function block are valid.
B Busy BOOL For function blocks with Execute input, the Busy output is set to TRUE upon the rising edge of the Execute, and set to FALSE when Done, CommandAborted or Error outputs becomes TRUE. In the case of a function block with an Enable input, Busy indicates that the function block is operating, but may not be ready to provide valid outputs.
B Error BOOL The Error output is set to TRUE if an error has occurred during the operation of the function block. The output is cleared when the Execute or Enable input becomes FALSE.
E ErrorID UINT The ErrorID output provides the identifier of the error when there is an active error in the function block execution. The output is cleared when the Execute or Enable input becomes FALSE.
B Value BOOL Value of the parameter.

Notes

Refer to boolean parameters in the Axis Parameter List.

Error Description

See the Function Block ErrorID List

Example

Instance of MC_ReadBoolParameter reading boolean parameter 1222 (LimitAccelEnable) which is TRUE by default.
MC_ReadBoolParameterExample.png

 