Security Guideline for iCube Engineer

This guideline provides instructions on how to securely handle the iCube Engineer software and your solutions/data created with/by the tool.

This topic contains the following sections:

Further Info
In addition to this topic, also read and observe the information given under "Recommended Security Measures for Devices and Solutions". Also consider the security-related information in the iCube Info Center which provides many information and practical user tips on the iC9200 Series control platform and iCube Engineer.

Note
Some tool-relating settings are only possible after launching iCube Engineer as Windows administrator. This includes, for example, the installation of certificates in iCube Engineer.
Such security-related administrator settings are possible in the 'Options' dialog.

General measures for PC-based software to reduce the risk of tampering

iCube Engineer can manipulate the device or solution. To reduce the risk of manipulation, perform security evaluations regularly.

PC-based hardening and organization measures

Protect any PCs used in automation solution environments against security-relevant manipulations. This can be facilitated, for example, by taking the following measures:

  • Boot up your PC regularly, and only from data carriers that are secured against manipulation.
  • Set up restrictive access rights for any personnel that absolutely must have authorization.
  • Protect your systems against unauthorized access with strong passwords and with rules to ensure that they remain strong.
  • Encrypt your project data.
  • Deactivate unused services.
  • Uninstall any software hat is not used.
  • Use a suitable and up-to-date virus/malware detection software.
  • Use a firewall to restrict access.
  • Use whitelist tools to protect important directories and data against unauthorized changes.
  • Activate security-relevant event logging in accordance with the security directive and the legal requirements on data protection.
  • Activate the update feature in accordance with the security directive.
  • Activate the automatic screen lock function and automatic logout after a specified time.
  • Perform backups regularly.
  • Only use data and software from approved sources.
  • Do not follow any hyperlinks listed that are from unknown sources, such as e-mails.

Use the latest software

  • Always use the latest iCube Engineer version as well as the latest operating system version on your PC.
  • Check for any iCube Engineer updates available. A corresponding link is available on the start page.
  • Observe the Change Notes for the respective software version.

Integrity verification of the downloaded setup file

To comply with the IEC 62443 standard, you have to verify that the downloaded iCube Engineer setup file has not been corrupted/tampered after downloading the setup and prior to the installation.

Running iCube Engineer with administrator rights

For some setup operations (for example, the installation of certificates in the trust store), iCube Engineer must be executed with administrator rights. While iCube Engineer is running with admin rights, installed plugins/add-ons and (also corrupted or manipulated) components may have unrestricted access to your system, data or controller hardware (and therefore possibly to your automation application).

Therefore, make sure that iCube Engineer is only started with admin rights if this is absolutely necessary. Exit iCube Engineer after you have made the required administrator settings and restart the software with normal user rights.

Protection of project data on the hard disk and during transfer

iCube Engineer currently stores plain, i.e., unencrypted project data on the harddisk of your computer. This also applies to project archives and exported libraries. The data is therefore unprotected against tampering and theft.

Use a suitable encryption method:

Suitable methods can be provided by encryption and signing tools according to the OpenPGP standard as defined by RFC 4880 (such as PGP, or GnuPG). For encrypting project data on your hard disk, for example, FDE (Full Disk Encryption) tools, such as BitLocker can be used. WinZip archives with password can help protect project files/archives or released libraries.

Furthermore, you can use a version control system with a secured repository to protect your solution data on hard disk/network drive.

Recommendation: Encryption on the entire data transmission path

Note
Peculiarities for the flat file format: The solution format 'Uncompressed Projects' (*.pcwef) is designed for the source data to be modified directly on the hard disk of your computer. This means that tamper protection by means of hashes and signatures is not possible. Use suitable measures to prevent and detect manipulation or loss of this data.
Alternatively you can use the compressed project format for your solution which enables the default data security provided by iCube Engineer.
To convert the solution, select 'File > Save Project As...' and choose the file type 'Compressed Projects (*.pcwex').

Protect project data by using a Version Control System

Solution data on your hard disk or on a network drive could be tampered by external attackers. One possible threat scenario is that an attacker completely replaces the source code of your solution. For example, the current solution data could be replaced by an outdated and (still) buggy version, which could then be written to the controller and put into operation if the intrusion is not detected.

A possible protection measure against this threat of manipulation is the use of a version control system for storing, archiving and versioning the iCube Engineer projects.

It should be noted that the VCS used should also be protected against unauthorized access and therefore manipulation. This applies to the communication between the VCS clients (iCube Engineer in our case) and the server where the repository is hosted as well as to the repository itself.

Another advantage of a VCS is that it is logged in the repository which iCube Engineer user has made which change to the project and when it was made. This change tracking is currently only implemented in iCube Engineer for the safety area.

Further Info
For detailed information, see the topic "Version Management using a VCS".

Installation check / tamper detection (administrator information)

Note
By default, access to the iCube Engineer installation folder is restricted to Windows admin users.

You have to continuously check the integrity of the iCube Engineer installation. For that purpose, you can use a standard Windows tool to verify that the iCube Engineer installation is not tampered/corrupted.

Use a tool which provides the possibility to calculate checksums over individual files as well as entire directories (including subfolders, if required). It can be executed for the iCube Engineer installation directory thus delivering a checksum over the iCube Engineer software installation.

This way, the resulting CRCs consider the following tool settings:

User settings (e.g., made in the 'Options' dialog) are not relevant for this kind of tamper detection as they do not result in any changes in the installation directory of iCube Engineer.

This way, any modification of the iCube Engineer installation can be detected by means of a differing checksum.

Close projects opened from a removable/network storage after use

When opening a project from a removable storage medium, such as an USB stick, or from a connected network drive, iCube Engineer creates shadow copies. While the project remains open and is edited/stored, changes are made to these shadow copies. When closing the project, these copies are automatically removed.

Shadow copies are stored on your computer under %APPDATA%\Roaming\Yaskawa\iCubeEngineer\${Version}\SHADOW (hidden folder).

Keep in mind that these shadow copies might be compromised, for example, by being modified, replaced, moved, deleted or read/copied by unauthorized access to your computer.

Recommendation: Always close projects opened from such locations after using them in iCube Engineer. Then the shadow copies are removed from your PC and no longer represent a potential security risk.

Security-related particularities regarding the Application Control Interface (ACI)

The Application Control Interface (ACI) is an internal interface of iCube Engineer which allows remote access to and controlling of the engineering tool. Using the ACI is the only way to operate or run iCube Engineer without the user interface.

The ACI has to be enabled/disabled via a checkbox in the 'Options' dialog: Select 'Extras > Options' and select the category 'Administration > Application Control Interface'.

Note
Enabling/disabling the ACI is only possible after launching iCube Engineer with Windows administrator rights and while no project is open.

Via the ACI, an external application can perform the same operations as via the iCube Engineer user interface. With regard to the security of the engineering tool and the controlled automation system, particular vulnerabilities arise from this possibility of remote controlling:

An unauthorized application may control the iCube Engineer via ACI. The communication connection is possibly not established between iCube Engineer and the ACI client but the engineering tool is connected to an attacker application.
Possible damage scenarios can be:

To prevent an unauthorized communication via the ACI interface, the connection between an ACI client and iCube Engineer is secured by means of a cookie which is stored on the engineering PC. This cookie is encrypted (using Windows Data Protection API) and is afterwards specifically bound to the user login. By verifying the cookie on connection establishment, the authenticity of the ACI client and iCube Engineer can be verified thus ensuring that the connection is authorized.

Observe the following regarding the ACI concerning cyber security:

 


This help information is valid for iCube Engineer Online Help 2025.6