Y_PK_UN_NotDone

Image

Reports the first instance of which EM and which CM has not finished the Current Acting State. If all modules are done, it will return 999 for both values.

Parameters

* Parameter Data Type Description Default
VAR_IN_OUT
E UnitMachine Yt_PK_UNitmachine_STRUCT Structure containing information about the machine's current state and operation modes for all EMs and CMs
VAR_IN
B Enable BOOL The function will continue to execute while the enable is held high FALSE
VAR_OUTPUT
B Valid BOOL Indicates that the outputs of the function are valid
B Error BOOL Set high if error has occurred during the execution of the function block. This output is cleared when 'Execute' or 'Enable' goes low.
B ErrorID UINT If Error is true, this output provides the Error ID. This output is reset when 'Execute' or 'Enable' goes low.
B EM INT The first instance of an EM that has not finished the Current Acting State. If all are finished, 999 will be returned.
B
CM INT The first instance of a CM that has not finished the Current Acting State. If all are finished, 999 will be returned.

Error Description:

See the Function Block ErrorID List.

 


This help information is valid for iCube Engineer Online Help 2025.6

Copyright © 2025 YASKAWA EUROPE GmbH and © 2025 YASKAWA America, Inc.