OverridePossible output

Output for the monitoring signal providing notification that an override operation is possible:

Data type: BOOL

Connection: Connect the OverridePossible output to an output terminal of your application (e.g., for an indicating device to signal that an override operation is possible), either directly or via other functions/function blocks.

ValueDescription
TRUEOverride operation is possible.

The following conditions must be met:

  • The function block has been activated (input Activate = TRUE)
  • and a muting error is present
  • and the light beam of the safety-related equipment (e.g., light barrier) is interrupted (S_AOPD_In = SAFEFALSE)
  • or at least one of the muting sensors detects an object.
FALSEOverride operation is not  possible.

The following conditions must be met:

  • The function block is not active (input Activate = FALSE)
  • or no muting error is present
  • or the light beam of the safety-related equipment (e.g., light barrier) is not interrupted (S_AOPD_In = SAFETRUE)
  • or none of the muting sensors detects an object.

WARNING
Non-conformance to safety function requirements
  • Be sure that your risk analysis includes an evaluation of a manual override operation (S_StartStopOverride = SAFETRUE).
  • Observe the regulations given by relevant sector standards regarding the override operation.
  • Make certain that appropriate procedures and measures (according to applicable sector standards) have been established to help avoid hazardous situations when activating the override operation.

 


This help information is valid for iCube Engineer Online Help 2025.6

Copyright © 2025 YASKAWA EUROPE GmbH and © 2025 YASKAWA America, Inc.